Need a different size or spec? Use the quote form above or call (877) 703-7699. Why this beats a big-box kit · How to prep your floor
For shops, warehouses, showrooms and retail floors. Solid Color: B-707 High Build Epoxy with T-322 VOC-compliant solvent polyurethane, the hard, chemical-resistant topcoat for forklifts and hot tires. Full Flake: B-707, a full flake broadcast, T-444X polyaspartic clear. Full tool kit included. Above 5,000 sq ft, call (877) 703-7699 for a quote and drum pricing.
What's in the box
Solid Color
- Up to 2,000 sq ft: B-707 15 gal kit + B-707 3 gal kit + T-322 topcoat 2 x 3 gal kit + tool kit
- Up to 5,000 sq ft: 3 x B-707 15 gal kit + T-322 topcoat 15 gal kit + tool kit
Full Flake
- Up to 2,000 sq ft: B-707 15 gal + 3 gal kit + 6 x 40 lb box of flake + T-444X 10 gal clear + tool kit
- Up to 5,000 sq ft: 3 x B-707 15 gal kit + 15 x 40 lb box of flake + 2 x T-444X 10 gal clear + tool kit
The tool kit: 18 inch roller frame and two covers, 18 inch notched squeegee, mix wand, chip brush, spiked shoes, mixing bucket, gloves and safety glasses. Larger floors want a second frame and a spray rig; ask when you call.
Coverage figures assume the recommended thickness on a properly profiled slab. Rough or porous concrete uses more. Order the next size up if your floor is at the top of a range.
Before you start, check the floor
- Moisture. Tape a 2 ft square of plastic sheet to the slab, seal the edges, wait 24 hours. Water under the plastic or a dark spot means the slab is damp. Prime it with P-409 Moisture Vapor Primer first, or the floor will lift.
- Cracks and spalls. Fill cracks with R-818 Epoxy Crack Filler. Rebuild spalls and holes with R-343 Concrete Quick Fix. Fill saw-cut and expansion joints with R-830 Flexible Joint Sealant.
- Oil stains. If a stain comes back a day after degreasing, the oil is in the slab. Prime those spots with P-820 Oil Stop Primer.
- Profile. Grind or acid-etch the concrete so it feels like 120-grit sandpaper. Coatings bond to profile, not to smooth concrete.
- Temperature. Slab and air between 60 and 90°F for epoxy (45°F for the cold-weather products and polyurea). Humidity under 85%.
Shipping restriction
T-322 meets the federal limit and the older OTC and MRPO limits. It cannot ship to CA, CO, CT, DE, MD, MI, NY, OH, RI or UT, which set a stricter limit. Floors in those states: call for a water-based or polyaspartic alternative.
Not included
- Moisture vapor primer (P-409) if the slab tests damp
- Crack, spall and joint repair (R-818, R-343, R-830)
- Anti-slip aggregate for ramps and wet areas (A-HWS)